Model | Application | Type | Capsule | Measurement Span | Maximum Working Pressure | |||
kPa | inH2O | MPa | psi | |||||
![]() EJA110E |
Differential Pressure |
Traditional- Mounting*1 |
F M H V |
0.5 to 5 1 to 100 5 to 500 0.14 to 14 MPa |
2 to 20 4 to 400 20 to 2000 20 to 2000 psi |
16 16 16 16 |
2300 2300 2300 2300 |
|
![]() EJA115E |
Flow |
Integral Orifice |
F M H |
1 to 5 2 to 100 20 to 210 |
4 to 20 8 to 400 80 to 830 |
16 16 16 |
2300 2300 2300 |
|
![]() EJA118E |
Differential Pressure & Liquid Level with Remote Seals |
Extended Flush Combination |
M H |
2.5 to 100 25 to 500 |
10 to 400 100 to 2000 |
Based on Flange Rating | ||
![]() EJA120E |
Draft Range |
Traditional- Mounting*1 |
E | 0.1 to 1 | 0.4 to 4 | 50 kPa | 7.25 | |
![]() EJA130E |
Differential Pressure & Liquid Level |
Traditional- Mounting*1 |
M H |
1 to 100 5 to 500 |
4 to 400 20 to 2000 |
32 32 |
4500 4500 |
|
![]() EJA210E |
Liquid Level, (Closed or Open Tank) |
Flush Extended |
M H |
1 to 100 5 to 500 |
4 to 400 20 to 2000 |
Based on Flange Rating | ||
![]() EJA310E |
Absolute (Vacuum) Pressure*2 |
Traditional- Mounting*1 |
L M A B |
0.67 to 10 1.3 to 130 0.03 to 3.5 MPa 0.14 to 16 MPa |
0.2 to 2.95 inHg 0.39 to 38 inHg 4.3 to 500 psi 20 to 2300 psi |
10 kPa 130 kPa 3.5 16 |
2.95 inHg 38 inHg 500 2300 |
|
![]() EJA430E |
Gauge Pressure |
Traditional- Mounting*1 |
H A B |
5 to 500 0.03 to 3.5 MPa 0.14 to 16 MPa |
20 to 2000 4.3 to 500 psi 20 to 2300 psi |
500 kPa 3.5 16 |
2000 inH2O 500 2300 |
|
![]() EJA438E |
Gauge Pressure with Remote Seal |
Flush |
A B |
0.06 to 3.5 MPa 0.46 to 16 MPa |
8.6 to 500 psi 66 to 2300 psi |
Based on Flange Rating | ||
Extended |
A B |
0.06 to 3.5 MPa 0.46 to 7 MPa |
8.6 to 500 psi 66 to 1000 psi |
|||||
![]() EJA440E |
High Gauge |
Traditional- Mounting*1 |
C D |
5 to 32 MPa 5 to 50 MPa |
720 to 4500 psi 720 to 7200 psi |
32 50 |
4500 7200 |
|
![]() EJA510E EJA530E |
Absolute & Gauge Pressure*2 |
Direct- Mounting |
A B C D |
10 to 200 0.1 to 2 MPa 0.5 to 10 MPa 5 to 50 MPa |
1.45 to 29 psi 14.5 to 290 psi 72.5 to 1450 psi 720 to 7200 psi |
200 kPa 2 10 50 |
29 290 1450 7200 |
*1: | Traditional-Mounting is 1/4NPT or Rc1/4 process connections (1/2NPT or Rc1/2 with process adapter). |
*2: | Measurement values in Absolute for Absolute Pressure Transmitter. |